History
MATACHANA is a family-owned company with 60 years of experience, 4 European production sites, and operations in over 120 countries. World leader in the manufacture of steam sterilization equipment, different low-temperature sterilization technologies, washing and disinfection equipment, provides comprehensive solutions for the Healthcare, Life Science and Pharma sectors.
MATACHANA has been ISO 9001 certified since 1995, awarded by Lloyd’s Register LRQA Ltd., as well as for medical devices; ISO 13485 is currently extended by TÜV Rheinland LGA Products GmbH and other specific qualifications from the various countries in which operates. In addition, all sterilizations equipment complies with the different applicable European directives.
Product Items
- Steam sterilisers Matachana 2000 I
- Steam sterilizers Matachana S1500 I
- Steam sterilisers Matachana SC500 I
- Steam Sterilizers Matachana S1000 I
Steam sterilization in animal facilities, industry, and laboratories involves very defined specifications and requirements. For this reason, MATACHANA sterilizers are designed and developed to provide maximum continuous performance at the highest quality in these types of environments and centres. They cover various applications and programs, including processes for bedding boxes, feed, glassware, instruments, porous loads, liquids (open and closed) and other laboratory elements.MATACHANA, they are committed and aware of the importance of reducing the consumption of our equipment so that they can use less energy to carry out the same tasks.

*Suitable for laboratories and the industry, as well as any other center that requires fast and safe sterilization of large volume.
Main features of our systems
Matachana 2000 I
Models | 2.1000LV | 2.1300LV | 2.1560LV | 2.2100LV | 2.3100LV | 2.6637LV | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1l | 2l | 1l | 2l | 1l | 2l | 1l | 2l | 1l | 2l | 1l | 2l | ||||||||||||
Height | 1440 | 1440 | 1440 | 1440 | 1440 | 2150 | |||||||||||||||||
Chamber Dimensions(mm)HeightWidthDepth | 1440700960 | 14407001264 | 14409601264 | 14409601520 | 14409602400 | 215012602450 | |||||||||||||||||
Total dimensions(mm)HeightWidthDepth | 212019501375 | 212019501490 | 212019501679 | 212019501794 | 212024101770 | 212024101770 | 212024102030 | 212024102030 | 212024102910 | 212024102910 | 212031003030 | 212031003030 | |||||||||||
Chamber volume(liters) | 961 | 961 | 1265 | 1265 | 1747 | 1747 | 2101 | 2101 | 3318 | 3318 | 6637 | 6637 | |||||||||||
Power(kW) | 5 | 5 | 5 | 7 | 7 | 18 |
The ideal for research centres, animal facilities, microbiology laboratories, BSL-2 and BSL-3 areas, and general sterile material supply industries, which must ensure speed and safety within their large-volume sterilization processes.
Vacuum system using ejector-venturi, silent and performant with water-saving solution (sterilizers up to 3 m3) or by liquid-ring pump (from 3 m3). Control system through two PLCs (control and register), which ensures independent readings (temperature/pressure) in which all operations monitoring of the unit are centralized. Enables easy and intuitive handling.
- Sterilization programs for solid material, adjustable temperatures between 115 and 135 C.
- Connecting to an external cooling system with substantial water savings and reduced cycle time.
- Natural cooling or by jacket flooding + sterile air counter pressure for open liquids programs.
- Air treatment system through a 0,2 μ self-sterilizable filter condensate line and condensates treatment inside the chamber for potentially contaminated areas and material (ex., BSL-2, BSL-3 zones, etc.).
Matachana S1500 I
EC models | 1506V-1l|156V-2l | 1506E-1l|1506E-2l | 1509V-1l|1509V-2l | 1509E-1l|1509E-2l | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
USA models | NA15.600LV-1A|NA15.600LV-2A | NA15.600LE-1A|NA15.600LE-2A | NA15.800LV-1A|NA15.800LV-2A | NA15.800LE-1A|NA15.800LE-2A | ||||||||||
Chamber Dimensions(mm) | mm | in | mm | in | mm | in | mm | in | ||||||
WidthHeightDepth | 6701100770 | 26 3/843 1/430 3/8 | 67011001100 | 26 3/843 1/430 3/8 | 67011001100 | 26 3/843 1/443 1/4 | 67011001100 | 26 3/843 1/443 1/4 | ||||||
Total dimensions | mm | in | mm | in | mm | in | mm | in | ||||||
WidthHeightDepth | 180020001240 | 70 7/878 3/448 7/8 | 180025001240 | 70 7/898 3/848 7/8 | 180020001570 | 70 7/878 3/461 3/4 | 180025001570 | 70 7/898 3/861 3/4 | ||||||
Chamber volume | liters | ft3 | liters | ft3 | liters | ft3 | liters | ft3 | ||||||
567 | 20 | 567 | 20 | 810 | 28.6 | 810 | 28.6 | |||||||
Power | kW | kW | kW | kW | ||||||||||
CE modelsUSA models | 23 | 3939 | 23 | 5151 | ||||||||||
Votage/Frequency | 3~/50-60Hz |
The S1500 I Series is a family of devices that complements the line of high-capacity steam sterilizers. These units combine productivity and cost-effectiveness.
FLEXIBILITY
Flexibility in selecting a wide range of sterilizers with different chamber sizes and volumes, which cover and respond to any specific need of our customers.
ERGONOMICS
Ergonomics through user-friendly loading systems, facilitating the dynamics and workflow in the different areas while providing practical and specific solutions for each project.
ECO-EFFICIENCY
Committed to maintenance and environmental protection, the S1500 I sterilizer, manufactured with recyclable materials, provides reduced energy consumption, which helps the customers improve the eco-efficiency of their installation.
- AutoStart and auto allow more ecological management of the sterilizer’s power consumption.
- Built-in heat recovery system.
- Vacuum system specially designed to reduce water consumption.
- Connection to external water recovery systems that reduce up to 99 % of the total water consumption of the device.
- Smart power consumption manager.
Matachana S1000 I
Models | SC500V-1l | SC500V-2l | SC501V-1l | SC501V-2l | SC502V-1l | SC502V-2l | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
SC500E-1l | SC500E-2l | SC501E-1l | SC501E-2l | SC502E-1l | SC502E-2l | ||||||
Technical specifications | 1 door | 2 doors | 1 door | 2 doors | 1 door | 2 doors | |||||
Total dimensions(mm)HeightWidthDepth | 1824900995 | 18249001009 | 18249001342 | 18249001355 | 18249001622 | 18249001635 | |||||
Chamber Dimensions(mm)(*)HeightWidthDepth | 500500675 | 5005001675 | 5005001020 | 5005001020 | 5005001300 | 5005001300 | |||||
Chamber volume(liters) | 167 | 167 | 252 | 252 | 321 | 321 | |||||
Power(kW)WITH generator (models E)WITHOUT generator(modles V) | 212 | 212 | 212 | 212 | 212 | 212 |
Models | 1006V-1l | 1006V-2l | 1008V-1l | 1008V-2l | 1010V-1l | 1010V-2l | 1012V-1l | 1012V-2l | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1006E-1l | 1006E-2l | 1008E-1l | 1008E-2l | 1010E-1l | 1010E-2l | 1012E-1l | 1012V-2l | |||||||
Technical specifications | 1 door | 2 doors | 1 door | 2 doors | 1 door | 2 doors | 1 door | 2 doors | ||||||
Total dimensions(mm)HeightWidthDepth | 19549961314 | 19549961336 | 19549961614 | 19549961636 | 19549962054 | 19549962076 | 19549962316 | 19549962338 | ||||||
Chamber Dimensions(mm)(*)HeightWidthDepth | 670670998 | 670670996 | 6706701265 | 6706701296 | 6706701735 | 6706701733 | 6706702000 | 6706701988 | ||||||
Chamber volume(liters) | 445 | 445 | 565 | 578 | 774 | 773 | 893 | 892 | ||||||
Power(kW)WITH generator (models E)WITHOUT generator(modles V) | 512,5 | 512,5 | 632,5 | 632,5 | 632,5 | 632,5 | 632,5 | 632,5 |
An example is the steam generator (in the devices fitted with it), which has an integrated “smart” economiser system. It is fully controlled by the sterilizer’s CPU so that the right amount of steam for the program is produced, adapting to the needs of pressure and temperature of the program selected and run. It is specifically designed to let in the appropriate water volume in the generator and at the right cycle time to minimize the consumption of treated water and power of the generator.
Highly performant vacuum using water ejector (Venturi system). It is a faster, silent, and water-saving system compared to other devices in the market. Allows the user to know the status of a device quickly and easily.
- Liquids into non-hermetically sealed receptacles with adjustable temperatures between 105 and 135 C, with a product probe inside the chamber.
- Low temperature, with adjustable values between 70 and 105 C.
- Gravity.
- Filters sterilization.